LISTING · TRS1274CS · STEEL HALL STRUCTURE, NEVER ERECTED

Steel hall structure 23 × 55 m: clear span, fabricated and never erected

This steel hall structure was fabricated for a workshop and storage hall. The project did not go ahead and the structure has never been erected. Thirteen haunched steel frames span 23.00 m without internal columns; the hall is 55.40 m long and covers 1,274 m². An open canopy bay of 4.60 m adjoins one gable. The structural calculation has been promised and will be checked before a binding offer is made.

Johann Thal · THAL REUSE SYSTEMS · 14 Nov 2026

TRS1274CS – Isometric view of the structure based on the planning drawings – schematic, not a photograph.
Isometric view of the structure based on the planning drawings – schematic, not a photograph.
23.00 mclear span, 13 haunched frames
55.40 mhall length · 60.00 m with canopy
1,274 m²covered, external dimension
6.90 / 7.85 meaves / ridge
5.00 mframe spacing, can be shortened bay by bay
by arrangementavailability · price on request

Location, full building documents and – where available – current photos are provided after a short qualification and signature of the THAL REUSE STANDARD Fair Use Agreement (TRS-FA).

Hall passport · issued 13 Nov 2026
TRS1274CS

Identification

Object ID
TRS1274CS
Long form
TRS-1274-CS-W23L55-01
Construction
steel portal frame hall, haunched frames
Description
structure for a workshop and storage hall, duo-pitch roof, canopy bay
Hall passport no.
HP-20261113-01
Location
exact location after qualification

Origin and documents

Erected
not erected – fabricated, unused
Structural calc.
promised, not yet received
Check
parts list, shop drawings and EN 1090 manufacturer certificate requested
Drawings
planning drawings 1:100: plans, sections, elevations

Geometry

Dimensions
23.00 × 55.40 m external (basis of the object ID); 60.00 m with canopy bay
Bays
13 grid lines: 10 × 5.00 m + end bay 4.75 m; canopy bay 4.60 m
Eaves / ridge
6.90 m / 7.85 m; underside of rafter at ridge 7.25 m
Roof pitch
approx. 4–5°, duo-pitch roof
Clear height
below the haunch not dimensioned – to be measured

Structure

Frames
13 haunched steel frames, 23.00 m clear span
Bracing
bracing in one bay near each end of the hall
Steel
sections and steel grades as per calculation – to follow

Envelope and equipment

Roof
not part of the structure; insulated profiled sheeting was planned
Doors / rooflights
planned: 5 sectional doors 5.00 × 6.00 m, ridge rooflight – not part of the structure

Terms

Price
on request after qualification
Availability
by arrangement
Scope
steel structure, unused; scope (purlins, side rails, bracing, canopy) being clarified
Not included
foundations, floor slab, roof and wall cladding, doors, office fit-out
Status
fabricated, never erected; documents under review

Fabricated, but never erected

The hall was planned for servicing construction machinery, with five sectional doors of 5.00 × 6.00 m, a ridge rooflight and insulated profiled sheeting. That shows what the geometry is designed for – lorries, excavators and wheel loaders drive in without restriction.

  • Clear span: 23.00 m free width over 1,274 m² – no internal column in the way of racking, workstations or traffic routes.
  • Tall: eaves at 6.90 m – doors up to 6.00 m high and tall racking are possible.
  • Adaptable: the 5 m grid allows the hall to be shortened bay by bay – for example to nine bays of about 50 m or eight bays of about 45 m.

Dimensions at a glance

The object ID is derived from the external dimensions of the hall. All dimensions are taken from the planning drawings.

ReferenceValueNote
Hall body23.00 × 55.40 m1,274 m², external
Overall length60.00 mwith open canopy bay 4.60 m
Grid10 × 5.00 m + 4.75 m13 frame lines
Eaves / ridge6.90 / 7.85 munderside of rafter at ridge 7.25 m
Roof pitchapprox. 4–5°duo-pitch roof

What is available and what is still being checked

This article is based on the planning drawings at a scale of 1:100. They define geometry, grid and heights; sections, steel grades and connections refer to the structural calculation. The calculation has been promised. Shop and erection drawings, the parts list with weights and the EN 1090 manufacturer certificate have been requested, as has confirmation of the exact scope of supply. We will only make a binding offer once these documents have been checked, and will then add sections, tonnage and verified loads. The drawings are labelled in German.

TRS1274CS – Sheet 02: cross-section of the main frame with levels – sections as per calculation.
Sheet 02: cross-section of the main frame with levels – sections as per calculation.
TRS1274CS – Sheet 01: grid and column layout with braced bays and planned door openings.
Sheet 01: grid and column layout with braced bays and planned door openings.

Range of application under the Eurocodes (indicative)

The structure was designed for an upland site. Until the calculation is available, the load assumptions of that site serve as the design assumption: ground snow load sk = 0.96 kN/m² and basic velocity pressure qb = 0.33 kN/m² to Eurocode 1. Transferred to the German load zones this gives:

ActionZoneLimitClassification
Snowzone 1up to approx. 555 m a.s.l.probably without strengthening
Snowzone 1aup to approx. 465 m a.s.l.probably without strengthening
Snowzone 2up to approx. 320 m a.s.l.probably without strengthening
Snowzone 2aup to approx. 255 m a.s.l.probably without strengthening
Snowzone 3, North German lowlands–probably with strengthening
WindWZ 1 inland0.32 kN/m²probably without strengthening
WindWZ 2–3 inland0.39–0.47 kN/m²probably with strengthening

The information on the range of application and on possible strengthening measures is an indicative assessment based on the available documents. It does not replace a structural calculation. THAL REUSE SYSTEMS accepts no liability for it. Suitability for a specific site and the type and extent of any strengthening must be verified by a structural engineer appointed by the buyer.

Suitable second uses

Workshop and maintenance hall for construction, agricultural and municipal machinery; lorry and commercial vehicle service; storage and logistics hall; production hall for metalwork or timber construction; agricultural machinery and storage hall. The canopy bay can be omitted or built as an enclosed bay.

Steps to erection

The next step is to check the structural calculation and inspect the structure. You receive the complete documents after signing a confidentiality agreement. Foundations, floor slab and envelope are designed for the new site by the buyer’s architect or structural engineer; erection and cladding can be arranged through the TRS partner network. As the structure has already been fabricated, there is no lead time for new steelwork.

Frequently asked questions

What does the hall cost? We quote the price on request after a short qualification.

Is there a structural calculation? It has been promised by the seller but we have not yet received it. Until then all load figures are assumptions; we only make a binding offer after checking it.

Can the hall be built shorter? Yes. With the regular 5.00 m grid it can be shortened bay by bay, for example to about 50 m or 45 m. The bracing then has to be verified again.

Request documents

After qualification you receive location, exposé, hall passport and building documents. Please quote object ID TRS1274CS.

Johann Thal · Founder THAL REUSE SYSTEMS
Phone +49 30 80584249 · sales@thalreuse.systems · thalreuse.systems

Would you like to sell a hall? Talk to us – we buy or find the right buyer through our network. Offer a hall →

All details are based on the planning drawings and are given without warranty; dimensions are approximate. Subject to prior sale. This article does not replace design, structural or permit checks at the new site.

Drawings: © THAL REUSE SYSTEMS