Steel hall structure, two-aisle 20 × 43 m: fabricated and never erected

This steel hall structure was fabricated for a supermarket. The project was not realised and the structure has never been erected. The main hall measures 20.26 × 42.76 m and has two aisles with a row of columns on the centre line; lower wings and canopies bring the roofed area to about 1,870 m². Structural calculation, shop drawings and quantity list are available.

Johann Thal · THAL REUSE SYSTEMS · 26 Nov 2026

TRS1870MSF – Sheet 05: isometric view of the whole structure based on the shop drawings – schematic, not a photograph.
Sheet 05: isometric view of the whole structure based on the shop drawings – schematic, not a photograph.
20.26 mmain hall width, two aisles (2 × 10.13 m)
42.76 mmain hall length, 7 frame bays
approx. 1,870 m²roofed in total, main hall ≈ 870 m²
6.28 / 6.49 meaves / ridge, parapet 7.00 m
approx. 58 tsteel, execution class EXC2
by arrangementavailability · price on request

Location, full building documents and – where available – current photos are provided after a short qualification and signature of the THAL REUSE STANDARD Fair Use Agreement (TRS-FA).

Hall passport · issued 26 Nov 2026
TRS1870MSF

Identification

Object ID
TRS1870MSF
Long form
TRS-1870-MSF-W20L43-01
Construction
steel portal frame hall, two aisles, frames with centre columns
Description
structure for a supermarket: tall main hall, lower wings, flat roof with parapet, canopies
Hall passport no.
HP-20261126-01
Location
exact location after qualification

Origin and documents

Erected
not erected – fabricated, unused
Structural calc.
original structural calculation 11/2018–01/2020, about 790 pages; loads to Eurocode 1 with National Annexes (edition 2010-12, as of 11/2018)
Drawings
37 shop drawings (PDF and CAD), 3 position plans, quantity list (18 pages)

Geometry

Dimensions
main hall 20.26 × 42.76 m grid dimension (≈ 870 m²); roofed area in total approx. 1,870 m² (basis of the object ID)
Bays
8 frame lines, 7 bays of 6.10–6.13 m; aisles 2 × 10.13 m; side wing 3 × 5.315 m
Eaves / ridge
main hall: eaves 6.28 m, ridge 6.49 m (top of steel), parapet 7.00 m; side wing: top of steel 4.23 m, parapet 4.88 m
Roof pitch
approx. 1.2–1.5°, shallow pitch with parapet
Clear height
below the rafters not dimensioned – to be measured on the structure

Structure

Frames
8 steel frames in the main hall, two aisles with a centre column on line C; wings with their own frames
Bracing
roof and wall bracing of tube and bar sections
Steel
approx. 58 t per quantity list (05.02.2020), execution class EXC2; sections and grades as per calculation
Connections
bolted connections; long edge beams of the wings split for transport

Envelope and equipment

Roof
not part of the structure
Doors / rooflights
not part of the structure

Terms

Price
on request after qualification
Availability
by arrangement
Scope
steel structure with connection and fastening parts per quantity list
Not included
roof and wall envelope, doors, windows, foundations, floor slab, fit-out
Status
fabricated, never erected; documents available

Fabricated, but never erected

The structure was fabricated for a supermarket with a beverage store, storage and plant rooms. The project was not realised; according to the owner the structure has never been erected. The split into a tall main hall and lower annexes shows what the geometry is designed for: public access with a foyer and ancillary rooms.

  • Two aisles: two aisles of 10.13 m each, separated by a row of columns on the centre line – shorter rafter spans, but not column-free.
  • Tall and articulated: eaves 6.28 m, ridge 6.49 m, parapet 7.00 m; the lower wings (top of steel 4.23 m) take the entrance, ancillary rooms and plant.
  • Documented: structural calculation (about 790 pages), 37 shop drawings as PDF and CAD, position plans and quantity list are available.

Dimensions at a glance

The object ID is derived from the system dimension of the roofed area (approx. 1,870 m²). All dimensions are taken from the construction documents; areas are derived from the drawings and rounded.

ReferenceValueNote
Main hall20.26 × 42.76 m≈ 870 m², grid dimension
Aisles2 × 10.13 mrow of columns on line C
Frame bays7 × 6.10–6.13 m8 frame lines
Eaves / ridge6.28 / 6.49 mtop of steel; parapet 7.00 m
Side wing15.945 × 18.33 mtop of steel 4.23 m, parapet 4.88 m
Roofed areaapprox. 1,870 m²main hall, wings and canopies

What is available and what is still being checked

Available are the structural calculation of about 790 pages (11/2018 to 01/2020), three position plans, 37 shop drawings as PDF and CAD and an 18-page quantity list. The exact scope of supply is still being clarified: the purchase item is the steel structure as per the quantity list; envelope, doors, foundations, floor slab and fit-out are not included. Some long edge beams of the wings were split for transport. The buyer checks the condition of the coating after storage during the inspection. We release the documents after a framework agreement has been signed. The drawings are labelled in German.

TRS1870MSF – Sheet 02: cross-section B–B through main aisle and side wing with levels and centre column – schematic.
Sheet 02: cross-section B–B through main aisle and side wing with levels and centre column – schematic.
TRS1870MSF – Sheet 01: column layout with grid lines A–H and rows 1–8; outline of the angled wing and canopies schematic.
Sheet 01: column layout with grid lines A–H and rows 1–8; outline of the angled wing and canopies schematic.

Range of application under the Eurocodes (indicative)

The original structural calculation assumes in its load determination (as of 11/2018) snow load zone 2 (ground snow load sk = 0.85 kN/m²) and wind zone 1 (basic velocity pressure qb,0 = 0.32 kN/m², building height 6.90 m) to Eurocode 1 with the National Annexes, edition 2010-12. Compared with the current National Annex (DIN EN 1991-1-3/NA:2019-04, DIN EN 1991-1-4/NA:2010-12), the German load zones give:

ActionZoneLimitClassification
Snowzone 1up to approx. 505 m a.s.l.probably without strengthening
Snowzone 1aup to approx. 415 m a.s.l.probably without strengthening
Snowzone 2up to approx. 285 m a.s.l.probably without strengthening
Snowzone 2a–probably with strengthening
Snowzone 3, North German lowlands–probably with strengthening
WindWZ 1 inland0.32 kN/m²probably without strengthening
WindWZ 2–3 inland0.39–0.47 kN/m²probably with strengthening

The seismic action cannot be read from the available extracts and remains open. Foundations and anchorage are designed anew at the new site; the move to the second generation of Eurocodes will change the code basis in future. Usual strengthening measures, named but not designed: additional braced bays, closer purlin and side-rail spacing, knee braces, section reinforcement and lighter roof and wall cladding.

The information on the range of application and on possible strengthening measures is an indicative assessment based on the available documents. It does not replace a structural calculation. THAL REUSE SYSTEMS accepts no liability for it. Suitability for a specific site and the type and extent of any strengthening must be verified by a structural engineer appointed by the buyer.

Suitable second uses

Assembly and event space with ancillary rooms; community, club and education buildings; retail, showroom and car dealership; storage and production. Assembly spaces must meet the requirements of the respective assembly-venue regulations, for example on escape routes, fire protection and ventilation. The row of centre columns can be planned as a central aisle or room divider but limits free sightlines.

Steps to erection

The next step is a short framework agreement (TRS-FA); afterwards you receive the documents, the storage location and an inspection appointment. A licensed structural engineer confirms suitability for your site; the purchase decision should depend on that confirmation. Loading, transport and erection are to be considered separately from the purchase and can be carried out by the buyer or by qualified hall builders from the TRS partner network. Foundations, floor slab and envelope are designed by the buyer’s architect or structural engineer. As the structure has already been fabricated, there is no lead time for new steelwork.

Frequently asked questions

What does the hall cost? We quote the price on request after a short qualification.

Is there a structural calculation? Yes. The original calculation (about 790 pages, 2018–2020) is available, together with position plans, 37 shop drawings and a quantity list. Suitability for a new site must be verified by a licensed structural engineer.

Is the hall column-free? No. The main hall has two aisles: a row of columns on the centre line divides it into two aisles of 10.13 m each. It can be used as a central aisle or room divider.

Request documents

After qualification you receive location, exposé, hall passport and building documents. Please quote object ID TRS1870MSF.

Johann Thal · Founder THAL REUSE SYSTEMS
Phone +49 30 80584249 · sales@thalreuse.systems · thalreuse.systems

Would you like to sell a hall? Talk to us – we buy or find the right buyer through our network. Offer a hall →

All details are based on the construction documents and are given without warranty; dimensions and areas are approximate. Subject to prior sale. This article does not replace design, structural or permit checks at the new site.