Location and building documents are provided after a short qualification.
TRS263CSIdentification
- Object ID
- TRS263CS
- Code
- W7000-L42580-EH6500-RH6815
- Manufacturer / system
- GRAEFF Container- und Hallenbau, frame hall UNI PLUS 7
- Description
- clear-span steel frame hall with gable roof
- Hall passport no.
- 20261024
- Location
- Southern Germany, exact site after qualification
Origin and documents
- Erected
- 2008/09 (manufacturer design 09/2008)
- Conversion
- 2017: six door bays on the long side, sectional door in the east gable
- Drawings
- manufacturer drawings 2008, conversion drawings 2017
- Structural design
- reviewed before purchase
Geometry
- System dimension
- 6.26 × 42.00 m (basis of the object ID)
- Outer dimension
- 7.00 × 42.58 m
- Steel width
- 6.60 m outer edge of steel
- Grid
- 7 bays of 6.00 m, 8 frames
- Eaves / ridge
- 6.50 / 6.815 m
- Roof pitch
- 5°, gable roof
Structure
- Frames
- columns and rafters as designed, haunch at the frame corner
- Ridge joint
- end-plate splice, bolted
- Purlins
- C 200
- Wall rails
- C 160 in four rows
- Bracing
- roof in both end bays, walls in the closed end bays
- Column bases
- base plates with anchors on pad foundations
Envelope and equipment
- Walls
- trapezoidal sheeting with 60 mm mineral-fibre insulation
- Roof
- with 60 mm mineral-fibre insulation
- Colour
- RAL 9006 white aluminium
- Door bays
- 6 × 5.50 × 4.50 m on the north side
- Doors
- sectional door 4.00 × 4.50 m, personnel door in both gables
- Daylight / vents
- 2 rooflights 1.50 × 1.50 m with smoke vents
Terms
- Price
- on request after qualification
- Availability
- by arrangement
- Scope
- steel structure with envelope and equipment as agreed
- Not included
- land, foundations
- Dismantling
- by the buyer or via our partner hall builder
A slim system hall with an open long side
GRAEFF supplies the UNI PLUS 7 as a system hall of steel frames, purlins and wall rails. This hall was erected in 2008/09 and converted in 2017: since then the north side has been open on six of seven bays, with only the eastern end bay closed. It can therefore be served along its full length.
- Clear span: 7 m width without internal columns over 42.58 m length.
- Tall: 6.50 m eaves for forklifts, truck loading and high storage.
- Accessible along its length: six door bays of 5.50 × 4.50 m on the long side.


Dimensions on every reference level
The object ID is derived from the system dimension, i.e. the distance between frame axes at column centre. Outer dimensions matter for the plot and foundations.
| Reference | Width × length | Note |
|---|---|---|
| System dimension (axes, column centre) | 6.26 × 42.00 m | 263 m², basis of the object ID |
| Outer edge of steel (width) | 6.60 m | standard frame |
| Outer face of wall | 7.00 × 42.58 m | approx. 298 m² gross floor area |
| Door bays | 6 × 5.50 m | height 4.50 m, piers 0.50 m |
| Eaves / ridge | 6.50 / 6.815 m | roof pitch 5° |

Structure: eight steel frames on a 6.00 m grid
Eight steel frames carry the hall without internal columns. Columns and rafters are designed to the structural calculation, with a haunch at the frame corner and an end-plate splice at the ridge. C 200 purlins run over all seven bays; C 160 wall rails are arranged in four rows. Roof bracing sits in both end bays, wall bracing in the end bays of the closed walls.




The drawings are our own, redrawn from the building records. The original drawings and an on-site survey are authoritative.
Envelope, doors and daylight
The walls are trapezoidal sheeting with 60 mm mineral-fibre insulation, and the roof is also insulated with 60 mm mineral fibre; colour RAL 9006 white aluminium. The north side is open over six bays of 5.50 × 4.50 m. The east gable has a 4.00 × 4.50 m sectional door and a personnel door, the west gable a personnel door. Two 1.50 × 1.50 m rooflights with smoke and heat vents sit in the southern roof slope.
Design loads and classification
| Action | Design | Note |
|---|---|---|
| Snow | 0.85 kN/m² | as ground snow load roughly zone 2 up to approx. 285 m or zone 1 up to approx. 520 m a.s.l. (German annex) |
| Wind | per structural calculation | to be checked with the calculation |
The classification is an estimate and assumes that 0.85 kN/m² is the ground snow load; this will be checked against the structural calculation. A structural verification to Eurocode is required at the new site.
Possible uses
- Storage and materials hall served from the long side
- Shelter for vehicles and machinery
- Municipal or contractor's depot
- Bulk material or timber store
- Covered transhipment area
Dismantling and re-erection
- Survey: check against drawings, measure, mark components.
- Dismantling: cladding, purlins, rails, bracing and frames in reverse order of assembly.
- Transport: loading by component group.
- Foundations: new pad foundations as designed for the new site.
- Re-erection: new fasteners, re-tension bracing, check cladding.
For the building application at the new site we hand over the manufacturer and conversion drawings and, once reviewed, the structural calculation. On request we connect you with a hall builder for dismantling, transport and re-erection.
Frequently asked questions
What does the hall cost? We quote the price on request after a short qualification.
Who is the manufacturer? GRAEFF Container- und Hallenbau, frame hall UNI PLUS 7, erected in 2008/09.
Can the long side be closed again? Yes. The door bays can be closed with wall rails and cladding or fitted with doors; this is verified structurally.
Is the structure suitable for my site? The hall is designed for 0.85 kN/m² snow. A verification at the new site is always required.
Request documents
After qualification you receive location, exposé and building documents. Please quote the object ID TRS263CS.
Johann Thal · Founder THAL REUSE SYSTEMS
Phone +49 30 80584249 · sales@thalreuse.systems · thalreuse.systems
Would you like to sell a hall? Talk to us – we buy or find the right buyer through our network. Offer a hall →
All details are based on the building documents and a photo survey and are given without warranty; dimensions are approximate. Subject to prior sale. This article does not replace design, structural or permit checks at the new site. GRAEFF and UNI PLUS are trademarks of their respective owners; THAL REUSE SYSTEMS has no business relationship with the manufacturer.
Photos and drawings: © THAL REUSE SYSTEMS